Human Adenylate cyclase type 10 / ADCY10 ELISA Kit
- SKU:
- HUFI01235
- Product Type:
- ELISA Kit
- Size:
- 96 Assays
- Uniprot:
- Q96PN6
- Sensitivity:
- 46.875pg/ml
- Range:
- 78.125-5000pg/ml
- ELISA Type:
- Sandwich
- Synonyms:
- ADCY10, Adenylate cyclase type 10, Testicular soluble adenylyl cyclase, Germ cell soluble adenylyl cyclase, hsAC, sAC, AH-related protein, A, denylate cyclase homolog
- Reactivity:
- Human
- Research Area:
- Metabolism
Description
Human Adenylate cyclase type 10 / ADCY10 ELISA Kit
Adenylate cyclase type 10/ADCY10 encodes an adenylyl cyclase that is soluble and unaffected by G protein or forskolin signaling. The activity of Adenylate cyclase type 10/ADCY10 is controlled by bicarbonate. The transcriptional variation of Adenylate cyclase type 10/ADCY10 has been observed in persons with absorptive hypercalciuria. Alternative spliced transcripts encoding different isoforms have been identified. Adenylate cyclase type 10/ADCY10 has a pseudogene on chromosome 6. Hypercalciuria, absorptive, 2, and idiopathic hypercalciuria are all diseases associated with ADCY10. Sweet Taste Signaling and GPCR Signaling are two of the interconnected pathways of Adenylate cyclase type 10/ADCY10.
Product Name: | Human Adenylate cyclase type 10 / ADCY10 ELISA Kit |
Product Code: | HUFI01235 |
Size: | 96 Assays |
Alias: | ADCY10, Adenylate cyclase type 10, Testicular soluble adenylyl cyclase, Germ cell soluble adenylyl cyclase, hsAC, sAC, AH-related protein, A, denylate cyclase homolog |
Detection method: | Sandwich ELISA, Double Antibody |
Application: | This immunoassay kit allows for the in vitro quantitative determination of Human ADCY10 concentrations in serum plasma and other biological fluids. |
Sensitivity: | 46.875pg/ml |
Range: | 78.125-5000pg/ml |
Storage: | 4°C for 6 months |
Note: | For Research Use Only |
Recovery: | Matrices listed below were spiked with certain level of Human ADCY10 and the recovery rates were calculated by comparing the measured value to the expected amount of Human ADCY10 in samples. | ||||||||||||||||
| |||||||||||||||||
Linearity: | The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Human ADCY10 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected. | ||||||||||||||||
| |||||||||||||||||
CV(%): | Intra-Assay: CV<8% Inter-Assay: CV<10% |
Component | Quantity | Storage |
ELISA Microplate (Dismountable) | 8×12 strips | 4°C for 6 months |
Lyophilized Standard | 2 | 4°C/-20°C |
Sample/Standard Dilution Buffer | 20ml | 4°C |
Biotin-labeled Antibody(Concentrated) | 120ul | 4°C (Protect from light) |
Antibody Dilution Buffer | 10ml | 4°C |
HRP-Streptavidin Conjugate(SABC) | 120ul | 4°C (Protect from light) |
SABC Dilution Buffer | 10ml | 4°C |
TMB Substrate | 10ml | 4°C (Protect from light) |
Stop Solution | 10ml | 4°C |
Wash Buffer(25X) | 30ml | 4°C |
Plate Sealer | 5 | - |
Other materials and equipment required:
- Microplate reader with 450 nm wavelength filter
- Multichannel Pipette, Pipette, microcentrifuge tubes and disposable pipette tips
- Incubator
- Deionized or distilled water
- Absorbent paper
- Buffer resevoir
Uniprot | Q96PN6 |
UniProt Protein Function: | SAC: Soluble adenylyl cyclase that has a critical role in mammalian spermatogenesis. Produces the cAMP which mediates in part the cAMP-responsive nuclear factors indispensable for maturation of sperm in the epididymis. Induces capacitation, the maturational process that sperm undergo prior to fertilization. May be the bicarbonate sensor. Involved in ciliary beat regulation. Genetic variations in ADCY10 are a cause of susceptibility to hypercalciuria absorptive type 2 (HCA2). Absorptive hypercalciuria is a common type of hypercalciuria, a condition characterized by excessive urinary calcium excretion. Absorptive hypercalciuria is due to gastrointestinal hyperabsorption of calcium and is a frequent cause of calcium oxalate nephrolithiasis. Belongs to the adenylyl cyclase class-4/guanylyl cyclase family. 3 isoforms of the human protein are produced by alternative splicing. |
UniProt Protein Details: | Protein type:Adenylyl cyclase; Nucleotide Metabolism - purine; Lyase; EC 4.6.1.1 Chromosomal Location of Human Ortholog: 1q24 Cellular Component: growth cone; cytoskeleton; cell soma; perinuclear region of cytoplasm; apical part of cell; axon; dendrite; cytoplasm; plasma membrane; cytosol Molecular Function:manganese ion binding; magnesium ion binding; ATPase binding; ATP binding; adenylate cyclase activity Biological Process: positive regulation of apoptosis; cAMP biosynthetic process; spermatogenesis Disease: Hypercalciuria, Absorptive, 2 |
UniProt Code: | Q96PN6 |
NCBI GenInfo Identifier: | 209976994 |
NCBI Gene ID: | 55811 |
NCBI Accession: | NP_060887 |
Molecular Weight: | 187kDa |
NCBI Full Name: | adenylate cyclase type 10 isoform 1 |
UniProt Protein Name: | Adenylate cyclase type 10 |
UniProt Synonym Protein Names: | AH-related protein; Adenylate cyclase homolog; Germ cell soluble adenylyl cyclase; hsAC; sAC; Testicular soluble adenylyl cyclase |
Protein Family: | Sacsin |
UniProt Gene Name: | ADCY10 |
UniProt Entry Name: | ADCYA_HUMAN |
*Note: Protocols are specific to each batch/lot. For the correct instructions please follow the protocol included in your kit.
Before adding to wells, equilibrate the SABC working solution and TMB substrate for at least 30 min at 37°C. When diluting samples and reagents, they must be mixed completely and evenly. It is recommended to plot a standard curve for each test.
Step | Protocol |
1. | Set standard, test sample and control (zero) wells on the pre-coated plate respectively, and then, record their positions. It is recommended to measure each standard and sample in duplicate. Wash plate 2 times before adding standard, sample and control (zero) wells! |
2. | Aliquot 0.1ml standard solutions into the standard wells. |
3. | Add 0.1 ml of Sample / Standard dilution buffer into the control (zero) well. |
4. | Add 0.1 ml of properly diluted sample ( Human serum, plasma, tissue homogenates and other biological fluids.) into test sample wells. |
5. | Seal the plate with a cover and incubate at 37 °C for 90 min. |
6. | Remove the cover and discard the plate content, clap the plate on the absorbent filter papers or other absorbent material. Do NOT let the wells completely dry at any time. Wash plate X2. |
7. | Add 0.1 ml of Biotin- detection antibody working solution into the above wells (standard, test sample & zero wells). Add the solution at the bottom of each well without touching the side wall. |
8. | Seal the plate with a cover and incubate at 37°C for 60 min. |
9. | Remove the cover, and wash plate 3 times with Wash buffer. Let wash buffer rest in wells for 1 min between each wash. |
10. | Add 0.1 ml of SABC working solution into each well, cover the plate and incubate at 37°C for 30 min. |
11. | Remove the cover and wash plate 5 times with Wash buffer, and each time let the wash buffer stay in the wells for 1-2 min. |
12. | Add 90 µl of TMB substrate into each well, cover the plate and incubate at 37°C in dark within 10-20 min. (Note: This incubation time is for reference use only, the optimal time should be determined by end user.) And the shades of blue can be seen in the first 3-4 wells (with most concentrated standard solutions), the other wells show no obvious color. |
13. | Add 50 µl of Stop solution into each well and mix thoroughly. The color changes into yellow immediately. |
14. | Read the O.D. absorbance at 450 nm in a microplate reader immediately after adding the stop solution. |
When carrying out an ELISA assay it is important to prepare your samples in order to achieve the best possible results. Below we have a list of procedures for the preparation of samples for different sample types.
Sample Type | Protocol |
Serum | If using serum separator tubes, allow samples to clot for 30 minutes at room temperature. Centrifuge for 10 minutes at 1,000x g. Collect the serum fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. If serum separator tubes are not being used, allow samples to clot overnight at 2-8°C. Centrifuge for 10 minutes at 1,000x g. Remove serum and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. |
Plasma | Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples at 4°C for 15 mins at 1000 × g within 30 mins of collection. Collect the plasma fraction and assay promptly or aliquot and store the samples at -80°C. Avoid multiple freeze-thaw cycles. Note: Over haemolysed samples are not suitable for use with this kit. |
Urine & Cerebrospinal Fluid | Collect the urine (mid-stream) in a sterile container, centrifuge for 20 mins at 2000-3000 rpm. Remove supernatant and assay immediately. If any precipitation is detected, repeat the centrifugation step. A similar protocol can be used for cerebrospinal fluid. |
Cell culture supernatant | Collect the cell culture media by pipette, followed by centrifugation at 4°C for 20 mins at 1500 rpm. Collect the clear supernatant and assay immediately. |
Cell lysates | Solubilize cells in lysis buffer and allow to sit on ice for 30 minutes. Centrifuge tubes at 14,000 x g for 5 minutes to remove insoluble material. Aliquot the supernatant into a new tube and discard the remaining whole cell extract. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C. |
Tissue homogenates | The preparation of tissue homogenates will vary depending upon tissue type. Rinse tissue with 1X PBS to remove excess blood & homogenize in 20ml of 1X PBS (including protease inhibitors) and store overnight at ≤ -20°C. Two freeze-thaw cycles are required to break the cell membranes. To further disrupt the cell membranes you can sonicate the samples. Centrifuge homogenates for 5 mins at 5000xg. Remove the supernatant and assay immediately or aliquot and store at -20°C or -80°C. |
Tissue lysates | Rinse tissue with PBS, cut into 1-2 mm pieces, and homogenize with a tissue homogenizer in PBS. Add an equal volume of RIPA buffer containing protease inhibitors and lyse tissues at room temperature for 30 minutes with gentle agitation. Centrifuge to remove debris. Quantify total protein concentration using a total protein assay. Assay immediately or aliquot and store at ≤ -20 °C. |
Breast Milk | Collect milk samples and centrifuge at 10,000 x g for 60 min at 4°C. Aliquot the supernatant and assay. For long term use, store samples at -80°C. Minimize freeze/thaw cycles. |
Fill out our quote form below and a dedicated member of staff will get back to you within one working day!