Food Science

AMOZ (Nitrofuran Furaltadone) ELISA Kit (FSES0002)

(No reviews yet) Write a Review
SKU:
FSES0002
Product Type:
ELISA Kit
Applications:
ELISA
Research Area:
Food Science

Description

Technical Manual

AMOZ (Nitrofuran Furaltadone) ELISA Kit

Kit Name: AMOZ (Nitrofuran Furaltadone) ELISA Kit
Kit Size: 96 Assays
Test Principle: This kit uses Competitive-ELISA as the method. It can detect Nitrofuran Furaltadone (AMOZ) in samples, such as honey, muscle, etc. This kit is composed of ELISA Microtiter plate, HRP conjugate, antibody working solution, standard and other supplementary reagents. The microtiter plate in this kit has been pre-coated with coupled antigen. During the reaction, AMOZ in the samples or standard competes with coupled antigen on the solid phase supporter for sites of anti- AMOZ antibody. Then Horseradish Peroxidase (HRP) conjugate is added to each microtiter plate well, and substrate reagent is added for color development. There is a negative correlation between the OD value of samples and the concentration of AMOZ. The concentration of AMOZ in the samples can be calculated by comparing the OD of the samples to the standard curve.
Sensitivity: 0.05 ppb (ng/mL)
Reaction Mode: 25°C, 45 min~15 min
Detection Limit: Muscle (livestock), Liver, Honey, Milk, Egg---0.1 ppb; Milk powder, Egg powder, Feed---0.1 ppb; Muscle (Fish, Shrimp) ---0.1 ppb
Cross Reactivity: Furaltadone metabolite---100%,Furazolidone metabolite---<0.1%, Aminohydantoin Hydrochloride---<0.1%, Nitrofurazone metabolite---<0.1% Milk powder, Egg powder, Feed---85%±25%
Sample Recovery Rate:
Kits Components:
Item Specifications
ELISA Microtiter plate 96 wells
Standard Liquid 1 mL each (0 ppb, 0.05 ppb, 0.15 ppb, 0.45 ppb, 1.35 ppb, 4.05 ppb)
Derivatization Reagent 10 mL
HRP Conjugate 5.5 mL
Antibody Working Solution 5.5 mL
Substrate Reagent A 6 mL
Substrate Reagent B 6 mL
Stop Solution 6 mL
20×Concentrated Wash Buffer 40 mL
2×Reconstitution Buffer 50 mL
Plate Sealer 3 pieces
Sealed Bag 1 piece
Manual 1 copy
Instruments: Microplate reader, Printer, Homogenizer, Nitrogen evaporators, Water bath Oscillators, Centrifuge, Graduated pipette, Balance (sensibility 0.01 g).
Micropipette: Single channel (20-200 uL, 100-1000 uL), Multichannel (30-300 uL).
Reagents: Ethyl acetate, N-hexane, NaOH, HCl, K2HPO4 3H2O, ZnSO4 7H2O, Concentrated HCl, Na2Fe (CN) 5 NO 2H2O.
Storage And Expiry Date: Store the kit at 2~8°C. Do not freeze any test kit components. Return any unused microwells to their original foil bag and reseal them together with the desiccant provided and further store at 2 - 8°C. Expiry date: expiration date is on the packing box.
View AllClose

0 Reviews

View AllClose