Signal Transduction
TUSC3 Colorimetric Cell-Based ELISA
- SKU:
- CBCAB01085
- Product Type:
- ELISA Kit
- ELISA Type:
- Cell Based
- Research Area:
- Signal Transduction
- Reactivity:
- Human
- Reactivity:
- Mouse
- Reactivity:
- Rat
- Detection Method:
- Colorimetric
Description
Product Name: | TUSC3 Colorimetric Cell-Based ELISA |
Product Code: | CBCAB01085 |
ELISA Type: | Cell-Based |
Target: | TUSC3 |
Reactivity: | Human, Mouse, Rat |
Dynamic Range: | > 5000 Cells |
Detection Method: | Colorimetric 450 nmStorage/Stability:4°C/6 Months |
Format: | 96-Well Microplate |
The TUSC3 Colorimetric Cell-Based ELISA Kit is a convenient, lysate-free, high throughput and sensitive assay kit that can detect TUSC3 protein expression profile in cells. The kit can be used for measuring the relative amounts of TUSC3 in cultured cells as well as screening for the effects that various treatments, inhibitors (ie siRNA or chemicals), or activators have on TUSC3.
Qualitative determination of TUSC3 concentration is achieved by an indirect ELISA format. In essence, TUSC3 is captured by TUSC3-specific primary antibodies while the HRP-conjugated secondary antibodies bind the Fc region of the primary antibody. Through this binding, the HRP enzyme conjugated to the secondary antibody can catalyze a colorimetric reaction upon substrate addition. Due to the qualitative nature of the Cell-Based ELISA, multiple normalization methods are needed:
1. | A monoclonal antibody specific for human GAPDH is included to serve as an internal positive control in normalizing the target absorbance values. |
2. | Following the colorimetric measurement of HRP activity via substrate addition, the Crystal Violet whole-cell staining method may be used to determine cell density. After staining, the results can be analysed by normalizing the absorbance values to cell amounts, by which the plating difference can be adjusted. |
Database Information: | Gene ID: 7991, UniProt ID: Q13454, OMIM: 601385/611093, Unigene: Hs.591845 |
Gene Symbol: | TUSC3 |
Sub Type: | None |
UniProt Protein Function: | TUSC3: Magnesium transporter. May be involved in N- glycosylation through its association with N-oligosaccharyl transferase. Defects in TUSC3 are the cause of mental retardation autosomal recessive type 7 (MRT7); also known as mental retardation non-syndromic autosomal recessive 7. Mental retardation is characterized by significantly sub-average general intellectual functioning associated with impairments in adaptative behavior and manifested during the developmental period. Non- syndromic mental retardation patients do not manifest other clinical signs. Belongs to the OST3/OST6 family. 2 isoforms of the human protein are produced by alternative splicing. |
UniProt Protein Details: | Protein type:Membrane protein, integral; Membrane protein, multi-pass Chromosomal Location of Human Ortholog: 8p22 Cellular Component: endoplasmic reticulum membrane; mitochondrion; oligosaccharyl transferase complex; plasma membrane Molecular Function:dolichyl-diphosphooligosaccharide-protein glycotransferase activity; magnesium ion transmembrane transporter activity Biological Process: cognition; magnesium ion transport; protein amino acid N-linked glycosylation via asparagine; transmembrane transport Disease: Mental Retardation, Autosomal Recessive 7 |
NCBI Summary: | This gene is a candidate tumor suppressor gene. It is located within a homozygously deleted region of a metastatic prostate cancer. The gene is expressed in most nonlymphoid human tissues including prostate, lung, liver, and colon. Expression was also detected in many epithelial tumor cell lines. Two transcript variants encoding distinct isoforms have been identified for this gene. [provided by RefSeq, Jul 2008] |
UniProt Code: | Q13454 |
NCBI GenInfo Identifier: | 6166601 |
NCBI Gene ID: | 7991 |
NCBI Accession: | Q13454.1 |
UniProt Secondary Accession: | Q13454,Q14911, Q14912, Q96FW0, A8MSM0, D3DSP2, |
UniProt Related Accession: | Q13454 |
Molecular Weight: | 40kDa |
NCBI Full Name: | Tumor suppressor candidate 3 |
NCBI Synonym Full Names: | tumor suppressor candidate 3 |
NCBI Official Symbol: | TUSC3 |
NCBI Official Synonym Symbols: | M33; N33; MRT7; MRT22; OST3A; D8S1992 |
NCBI Protein Information: | tumor suppressor candidate 3 |
UniProt Protein Name: | Tumor suppressor candidate 3 |
UniProt Synonym Protein Names: | Magnesium uptake/transporter TUSC3; Protein N33 |
Protein Family: | Tumor suppressor candidate |
UniProt Gene Name: | TUSC3 |
Component | Quantity |
96-Well Cell Culture Clear-Bottom Microplate | 2 plates |
10X TBS | 24 mL |
Quenching Buffer | 24 mL |
Blocking Buffer | 50 mL |
15X Wash Buffer | 50 mL |
Primary Antibody Diluent | 12 mL |
100x Anti-Phospho Target Antibody | 60 µL |
100x Anti-Target Antibody | 60 µL |
Anti-GAPDH Antibody | 60 µL |
HRP-Conjugated Anti-Rabbit IgG Antibody | 12 mL |
HRP-Conjugated Anti-Mouse IgG Antibody | 12 mL |
SDS Solution | 12 mL |
Stop Solution | 24 mL |
Ready-to-Use Substrate | 12 mL |
Crystal Violet Solution | 12 mL |
Adhesive Plate Seals | 2 seals |
The following materials and/or equipment are NOT provided in this kit but are necessary to successfully conduct the experiment:
- Microplate reader able to measure absorbance at 450 nm and/or 595 nm for Crystal Violet Cell Staining (Optional)
- Micropipettes with capability of measuring volumes ranging from 1 µL to 1 ml
- 37% formaldehyde (Sigma Cat# F-8775) or formaldehyde from other sources
- Squirt bottle, manifold dispenser, multichannel pipette reservoir or automated microplate washer
- Graph paper or computer software capable of generating or displaying logarithmic functions
- Absorbent papers or vacuum aspirator
- Test tubes or microfuge tubes capable of storing ≥1 ml
- Poly-L-Lysine (Sigma Cat# P4832 for suspension cells)
- Orbital shaker (optional)
- Deionized or sterile water
*Note: Protocols are specific to each batch/lot. For the correct instructions please follow the protocol included in your kit.
Step | Procedure |
1. | Seed 200 µL of 20,000 adherent cells in culture medium in each well of a 96-well plate. The plates included in the kit are sterile and treated for cell culture. For suspension cells and loosely attached cells, coat the plates with 100 µL of 10 µg/ml Poly-L-Lysine (not included) to each well of a 96-well plate for 30 minutes at 37°C prior to adding cells. |
2. | Incubate the cells for overnight at 37°C, 5% CO2. |
3. | Treat the cells as desired. |
4. | Remove the cell culture medium and rinse with 200 µL of 1x TBS, twice. |
5. | Fix the cells by incubating with 100 µL of Fixing Solution for 20 minutes at room temperature. The 4% formaldehyde is used for adherent cells and 8% formaldehyde is used for suspension cells and loosely attached cells. |
6. | Remove the Fixing Solution and wash the plate 3 times with 200 µL 1x Wash Buffer for five minutes each time with gentle shaking on the orbital shaker. The plate can be stored at 4°C for a week. |
7. | Add 100 µL of Quenching Buffer and incubate for 20 minutes at room temperature. |
8. | Wash the plate 3 times with 1x Wash Buffer for 5 minutes each time. |
9. | Add 200 µL of Blocking Buffer and incubate for 1 hour at room temperature. |
10. | Wash 3 times with 200 µL of 1x Wash Buffer for 5 minutes each time. |
11. | Add 50 µL of 1x primary antibodies (Anti-TUSC3 Antibody and/or Anti-GAPDH Antibody) to the corresponding wells, cover with Parafilm and incubate for 16 hours (overnight) at 4°C. If the target expression is known to be high, incubate for 2 hours at room temperature. |
12. | Wash 3 times with 200 µL of 1x Wash Buffer for 5 minutes each time. |
13. | Add 50 µL of 1x secondary antibodies (HRP-Conjugated AntiRabbit IgG Antibody or HRP-Conjugated Anti-Mouse IgG Antibody) to corresponding wells and incubate for 1.5 hours at room temperature. |
14. | Wash 3 times with 200 µL of 1x Wash Buffer for 5 minutes each time. |
15. | Add 50 µL of Ready-to-Use Substrate to each well and incubate for 30 minutes at room temperature in the dark. |
16. | Add 50 µL of Stop Solution to each well and read OD at 450 nm immediately using the microplate reader. |
(Additional Crystal Violet staining may be performed if desired – details of this may be found in the kit technical manual.)