Rat Signaling ELISA Kits 3
Rat ON (Osteonectin) CLIA Kit (RTES00421)
- SKU:
- RTES00421
- Product Type:
- ELISA Kit
- ELISA Type:
- CLIA Kit
- Size:
- 96 Assays
- Sensitivity:
- 7.5pg/mL
- Range:
- 12.5-800pg/mL
- ELISA Type:
- Sandwich
- Reactivity:
- Rat
- Sample Type:
- Serum, plasma and other biological fluids
Description
Assay type: | Sandwich |
Format: | 96T |
Assay time: | 4.5h |
Reactivity: | Rat |
Detection method: | Chemiluminescence |
Detection range: | 12.50-800 pg/mL |
Sensitivity: | 7.50 pg/mL |
Sample volume: | 100µL |
Sample type: | Serum, plasma and other biological fluids |
Repeatability: | CV < 15% |
Specificity: | This kit recognizes Rat ON in samples. No significant cross-reactivity or interference between Rat ON and analogues was observed. |
This kit uses Sandwich-CLIA as the method. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Rat ON. Standards or samples are added to the appropriate micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat ON and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well successively and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat ON, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit (RLU) value is measured spectrophotometrically by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Rat ON. The concentration of Rat ON in the samples can be calculated by comparing the RLU of the samples to the standard curve.
UniProt Protein Function: | Appears to regulate cell growth through interactions with the extracellular matrix and cytokines. Binds calcium and copper, several types of collagen, albumin, thrombospondin, PDGF and cell membranes. There are two calcium binding sites; an acidic domain that binds 5 to 8 Ca2+ with a low affinity and an EF-hand loop that binds a Ca2+ ion with a high affinity. |
NCBI Summary: | secreted structural protein; may be a component of collagen and the extracellular matrix [RGD, Feb 2006] |
UniProt Code: | P16975 |
NCBI GenInfo Identifier: | 6981574 |
NCBI Gene ID: | 24791 |
NCBI Accession: | NP_036788. 1 |
UniProt Secondary Accession: | P16975,O08953, Q6GSZ4, |
UniProt Related Accession: | P16975 |
Molecular Weight: | 34,296 Da |
NCBI Full Name: | SPARC |
NCBI Synonym Full Names: | secreted protein acidic and cysteine rich |
NCBI Official Symbol: | Sparc |
NCBI Protein Information: | SPARC |
UniProt Protein Name: | SPARC |
UniProt Synonym Protein Names: | Basement-membrane protein 40; BM-40; Osteonectin; ON; Secreted protein acidic and rich in cysteine |
UniProt Gene Name: | Sparc |
As the RLU values of the standard curve may vary according to the conditions of the actual assay performance (e. g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.
Concentration (pg/mL) | RLU | Average | Corrected |
800 | 50004 55280 | 52642 | 52616 |
400 | 21183 22285 | 21734 | 21708 |
200 | 10122 9294 | 9708 | 9682 |
100 | 4167 4937 | 4552 | 4526 |
50 | 2206 2170 | 2188 | 2162 |
25 | 1079 1041 | 1060 | 1034 |
12.50 | 475 543 | 509 | 483 |
0 | 26 26 | 26 | -- |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Rat ON were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Rat ON were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (pg/mL) | 36.39 | 68.57 | 308.25 | 33.26 | 69.64 | 289.09 |
Standard deviation | 3.86 | 7.17 | 20.41 | 2.94 | 6.43 | 32.70 |
C V (%) | 10.61 | 10.46 | 6.62 | 8.84 | 9.23 | 11.31 |
Recovery
The recovery of Rat ON spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
Serum (n=5) | 91-105 | 98 |
EDTA plasma (n=5) | 85-98 | 92 |
Cell culture media (n=5) | 101-115 | 108 |
Linearity
Samples were spiked with high concentrations of Rat ON and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Serum (n=5) | EDTA plasma (n=5) | Cell culture media (n=5) | ||
1:2 | Range (%) | 95-109 | 96-111 | 83-98 |
Average (%) | 101 | 103 | 90 | |
1:4 | Range (%) | 98-113 | 88-102 | 101-113 |
Average (%) | 106 | 94 | 106 | |
1:8 | Range (%) | 95-107 | 86-99 | 100-115 |
Average (%) | 101 | 92 | 109 | |
1:16 | Range (%) | 94-109 | 92-105 | 96-108 |
Average (%) | 100 | 99 | 103 |
An unopened kit can be stored at 4°C for 1 month. If the kit is not used within 1 month, store the items separately according to the following conditions once the kit is received.
Item | Specifications | Storage |
Micro CLIA Plate(Dismountable) | 8 wells ×12 strips | -20°C, 6 months |
Reference Standard | 2 vials | |
Concentrated Biotinylated Detection Ab (100×) | 1 vial, 120 µL | |
Concentrated HRP Conjugate (100×) | 1 vial, 120 µL | -20°C(shading light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 4°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | |
HRP Conjugate Diluent | 1 vial, 14 mL | |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | |
Substrate Reagent A | 1 vial, 5 mL | 4°C (shading light) |
Substrate Reagent B | 1 vial, 5 mL | 4°C (shading light) |
Plate Sealer | 5 pieces | |
Product Description | 1 copy | |
Certificate of Analysis | 1 copy |
- Set standard, test sample and control (zero) wells on the pre-coated plate and record theirpositions. It is recommended to measure each standard and sample in duplicate. Note: addall solutions to the bottom of the plate wells while avoiding contact with the well walls. Ensuresolutions do not foam when adding to the wells.
- Aliquot 100µl of standard solutions into the standard wells.
- Add 100µl of Sample / Standard dilution buffer into the control (zero) well.
- Add 100µl of properly diluted sample (serum, plasma, tissue homogenates and otherbiological fluids. ) into test sample wells.
- Cover the plate with the sealer provided in the kit and incubate for 90 min at 37°C.
- Aspirate the liquid from each well, do not wash. Immediately add 100µL of BiotinylatedDetection Ab working solution to each well. Cover the plate with a plate seal and gently mix. Incubate for 1 hour at 37°C.
- Aspirate or decant the solution from the plate and add 350µL of wash buffer to each welland incubate for 1-2 minutes at room temperature. Aspirate the solution from each well andclap the plate on absorbent filter paper to dry. Repeat this process 3 times. Note: a microplatewasher can be used in this step and other wash steps.
- Add 100µL of HRP Conjugate working solution to each well. Cover with a plate seal andincubate for 30 min at 37°C.
- Aspirate or decant the solution from each well. Repeat the wash process for five times asconducted in step 7.
- Add 100µL of Substrate mixture solution to each well. Cover with a new plate seal andincubate for no more than 5 min at 37°C. Protect the plate from light.
- Determine the RLU value of each well immediately.