Rat Signaling ELISA Kits 3
Rat FN (Fibronectin) CLIA Kit (RTES00355)
- SKU:
- RTES00355
- Product Type:
- ELISA Kit
- ELISA Type:
- CLIA Kit
- Size:
- 96 Assays
- Sensitivity:
- 0.19ng/mL
- Range:
- 0.31-20ng/mL
- ELISA Type:
- Sandwich
- Synonyms:
- FN1, CIG, ED-B, FINC, FNZ, GFND, GFND2, LETS, MSF
- Reactivity:
- Rat
- Sample Type:
- Serum, plasma and other biological fluids
- Research Area:
- Immunology
Description
Assay type: | Sandwich |
Format: | 96T |
Assay time: | 4.5h |
Reactivity: | Rat |
Detection method: | Chemiluminescence |
Detection range: | 0.31-20 ng/mL |
Sensitivity: | 0.19 ng/mL |
Sample volume: | 100µL |
Sample type: | Serum, plasma and other biological fluids |
Repeatability: | CV < 15% |
Specificity: | This kit recognizes Rat FN in samples. No significant cross-reactivity or interference between Rat FN and analogues was observed. |
This kit uses Sandwich-CLIA as the method. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Rat FN. Standards or samples are added to the appropriate micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Rat FN and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well successively and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Rat FN, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit (RLU) value is measured spectrophotometrically by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Rat FN. The concentration of Rat FN in the samples can be calculated by comparing the RLU of the samples to the standard curve.
UniProt Protein Function: | FN1: Fibronectins bind cell surfaces and various compounds including collagen, fibrin, heparin, DNA, and actin. Fibronectins are involved in cell adhesion, cell motility, opsonization, wound healing, and maintenance of cell shape. Defects in FN1 are the cause of glomerulopathy with fibronectin deposits type 2 (GFND2); also known as familial glomerular nephritis with fibronectin deposits or fibronectin glomerulopathy. GFND is a genetically heterogeneous autosomal dominant disorder characterized clinically by proteinuria, microscopic hematuria, and hypertension that leads to end-stage renal failure in the second to fifth decade of life. 15 isoforms of the human protein are produced by alternative splicing. |
UniProt Protein Details: | Protein type:Secreted; Motility/polarity/chemotaxis; Cell adhesion; Secreted, signal peptide Cellular Component: extracellular matrix; proteinaceous extracellular matrix; extracellular space; fibrinogen complex; apical plasma membrane; extracellular region; ER-Golgi intermediate compartment; basement membrane; basal lamina Molecular Function:heparin binding; integrin binding; protein binding; protease activator activity; protease binding; extracellular matrix structural constituent; mercury ion binding Biological Process: integrin activation; extracellular matrix organization and biogenesis; ossification; wound healing; positive regulation of chemotaxis; positive regulation of axon extension; cell-matrix adhesion; response to glucocorticoid stimulus; glial cell migration; regulation of cell shape; cell activation; response to ozone; acute-phase response; response to wounding; calcium-independent cell-matrix adhesion; cell-substrate junction assembly; angiogenesis; peptide cross-linking; cell adhesion; positive regulation of cell migration; negative regulation of apoptosis |
NCBI Summary: | extracellular matrix component; may play a role in fibrosis and tumor metastasis [RGD, Feb 2006] |
UniProt Code: | P04937 |
NCBI GenInfo Identifier: | 120178 |
NCBI Gene ID: | 25661 |
NCBI Accession: | P04937. 2 |
UniProt Related Accession: | P04937 |
Molecular Weight: | |
NCBI Full Name: | Fibronectin |
NCBI Synonym Full Names: | fibronectin 1 |
NCBI Official Symbol: | Fn1 |
NCBI Official Synonym Symbols: | fn-1; FIBNEC |
NCBI Protein Information: | fibronectin |
UniProt Protein Name: | Fibronectin |
Protein Family: | Fibronectin |
UniProt Gene Name: | Fn1 |
UniProt Entry Name: | FINC_RAT |
As the RLU values of the standard curve may vary according to the conditions of the actual assay performance (e. g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.
Concentration (ng/mL) | RLU | Average | Corrected |
20 | 33503 34461 | 33982 | 33950 |
10 | 11973 12967 | 12470 | 12438 |
5 | 5495 5005 | 5250 | 5218 |
2.5 | 2329 2719 | 2524 | 2492 |
1.25 | 1478 1288 | 1383 | 1351 |
0.63 | 894 840 | 867 | 835 |
0.31 | 591 655 | 623 | 591 |
0 | 31 33 | 32 | -- |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Rat FN were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Rat FN were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (ng/mL) | 1.09 | 1.75 | 8.62 | 1.18 | 1.65 | 9.26 |
Standard deviation | 0.13 | 0.17 | 0.55 | 0.10 | 0.19 | 1.03 |
C V (%) | 11.93 | 9.71 | 6.38 | 8.47 | 11.52 | 11.12 |
Recovery
The recovery of Rat FN spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
Serum (n=5) | 90-104 | 97 |
EDTA plasma (n=5) | 102-119 | 108 |
Cell culture media (n=5) | 87-98 | 93 |
Linearity
Samples were spiked with high concentrations of Rat FN and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Serum (n=5) | EDTA plasma (n=5) | Cell culture media (n=5) | ||
1:2 | Range (%) | 95-106 | 88-100 | 90-106 |
Average (%) | 100 | 95 | 97 | |
1:4 | Range (%) | 95-110 | 100-116 | 98-111 |
Average (%) | 100 | 108 | 105 | |
1:8 | Range (%) | 84-98 | 97-113 | 96-108 |
Average (%) | 91 | 103 | 101 | |
1:16 | Range (%) | 100-115 | 104-117 | 91-107 |
Average (%) | 108 | 109 | 97 |
An unopened kit can be stored at 4°C for 1 month. If the kit is not used within 1 month, store the items separately according to the following conditions once the kit is received.
Item | Specifications | Storage |
Micro CLIA Plate(Dismountable) | 8 wells ×12 strips | -20°C, 6 months |
Reference Standard | 2 vials | |
Concentrated Biotinylated Detection Ab (100×) | 1 vial, 120 µL | |
Concentrated HRP Conjugate (100×) | 1 vial, 120 µL | -20°C(shading light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 4°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | |
HRP Conjugate Diluent | 1 vial, 14 mL | |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | |
Substrate Reagent A | 1 vial, 5 mL | 4°C (shading light) |
Substrate Reagent B | 1 vial, 5 mL | 4°C (shading light) |
Plate Sealer | 5 pieces | |
Product Description | 1 copy | |
Certificate of Analysis | 1 copy |
- Set standard, test sample and control (zero) wells on the pre-coated plate and record theirpositions. It is recommended to measure each standard and sample in duplicate. Note: addall solutions to the bottom of the plate wells while avoiding contact with the well walls. Ensuresolutions do not foam when adding to the wells.
- Aliquot 100µl of standard solutions into the standard wells.
- Add 100µl of Sample / Standard dilution buffer into the control (zero) well.
- Add 100µl of properly diluted sample (serum, plasma, tissue homogenates and otherbiological fluids. ) into test sample wells.
- Cover the plate with the sealer provided in the kit and incubate for 90 min at 37°C.
- Aspirate the liquid from each well, do not wash. Immediately add 100µL of BiotinylatedDetection Ab working solution to each well. Cover the plate with a plate seal and gently mix. Incubate for 1 hour at 37°C.
- Aspirate or decant the solution from the plate and add 350µL of wash buffer to each welland incubate for 1-2 minutes at room temperature. Aspirate the solution from each well andclap the plate on absorbent filter paper to dry. Repeat this process 3 times. Note: a microplatewasher can be used in this step and other wash steps.
- Add 100µL of HRP Conjugate working solution to each well. Cover with a plate seal andincubate for 30 min at 37°C.
- Aspirate or decant the solution from each well. Repeat the wash process for five times asconducted in step 7.
- Add 100µL of Substrate mixture solution to each well. Cover with a new plate seal andincubate for no more than 5 min at 37°C. Protect the plate from light.
- Determine the RLU value of each well immediately.