Porcine Immunology ELISA Kits
Porcine E-Selectin / CD62E ELISA Kit
- SKU:
- PRFI00148
- Product Type:
- ELISA Kit
- Size:
- 96 Assays
- Uniprot:
- P98110
- Sensitivity:
- 0.094ng/ml
- Range:
- 0.156-10ng/ml
- ELISA Type:
- Sandwich
- Synonyms:
- E-Selectin, SELE, CD62E, CD62E, ELAM1, LECAM2, SELE, CD62 antigen-like family member E, CD62E, CD62E antigen, ELAM, ELAM-14
- Reactivity:
- Porcine
Description
Porcine E-Selectin / CD62E ELISA Kit
E-selectin, also known as endothelial selectin or CD62E, is a cell adhesion molecule that plays a crucial role in the immune response and inflammatory processes within the body.The porcine E-Selectin ELISA kit enables researchers to accurately measure E-selectin concentrations, and facilitates investigations into inflammation, cardiovascular health, and related research areas.
Key Features
Save Time | Pre-coated 96 well plate | |
Quick Start | Kit includes all necessary reagents | |
Publication Ready | Reproducible and reliable results |
Overview
Product Name: | Porcine SELE (E-Selectin) ELISA Kit |
Product Code: | PRFI00148 |
Size: | 96 Assays |
Alias: | E-Selectin, SELE, CD62E, CD62E, ELAM1, LECAM2, SELE, CD62 antigen-like family member E, CD62E, CD62E antigen, ELAM, ELAM-14 |
Detection Method: | Sandwich ELISA, Double Antibody |
Reactivity: | Porcine |
Sensitivity: | 0.094ng/ml |
Range: | 0.156-10ng/ml |
Storage: | 4°C for 6 months |
Note: | For Research Use Only |
Additional Information
Recovery | Matrices listed below were spiked with certain level of Porcine SELE and the recovery rates were calculated by comparing the measured value to the expected amount of Porcine SELE in samples. Please contact us for more information. |
Linearity: | The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Porcine SELE and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected. Please contact us for more information. |
Intra Assay | CV < 8% |
Inter Assay | CV < 10% |
Kit Components
Component | Quantity | Storage |
ELISA Microplate (Dismountable) | 8x12 strips | 4°C for 6 months |
Lyophilized Standard | 2 | 4°C/ -20°C |
Sample/Standard Dlution Buffer | 20ml | 4°C |
Biotin-labeled Antibody (Concentrated) | 120ul | 4°C (Protection from light) |
Antibody Dilution Buffer | 10ml | 4°C |
HRP-Streptavidin Conjugate (SABC) | 120ul | 4°C (Protect from light) |
SABC Dilution Buffer | 10ml | 4°C |
TMB Substrate | 10ml | 4°C (Protection from light) |
Stop Solution | 10ml | 4°C |
Wash Buffer (25X) | 30ml | 4°C |
Plate Sealer | 5 | - |
Other materials required:
- Microplate reader with 450 nm wavelength filter
- Multichannel Pipette, Pipette, microcentrifuge tubes and disposable pipette tips
- Incubator
- Deionized or distilled water
- Absorbent paper
- Buffer resevoir
Protocol
*Note: Protocols are specific to each batch/lot. For the exact instructions please follow the protocol included in your kit.
Before adding to wells, equilibrate the SABC working solution and TMB substrate for at least 30 min at 37°C. When diluting samples and reagents, they must be mixed completely and evenly. It is recommended to plot a standard curve for each test.
Step | Procedure |
1. | Set standard, test sample and control (zero) wells on the pre-coated plate respectively, and then, record their positions. It is recommended to measure each standard and sample in duplicate. Wash plate 2 times before adding standard, sample and control (zero) wells! |
2. | Aliquot 0.1ml standard solutions into the standard wells. |
3. | Add 0.1 ml of Sample / Standard dilution buffer into the control (zero) well. |
4. | Add 0.1 ml of properly diluted sample ( Human serum, plasma, tissue homogenates and other biological fluids.) into test sample wells. |
5. | Seal the plate with a cover and incubate at 37 °C for 90 min. |
6. | Remove the cover and discard the plate content, clap the plate on the absorbent filter papers or other absorbent material. Do NOT let the wells completely dry at any time. Wash plate X2. |
7. | Add 0.1 ml of Biotin- detection antibody working solution into the above wells (standard, test sample &am |