Human Cell Biology ELISA Kits 5
Human CX40 (Connexin 40) CLIA Kit (HUES00941)
- SKU:
- HUES00941
- Product Type:
- ELISA Kit
- ELISA Type:
- CLIA Kit
- Size:
- 96 Assays
- Sensitivity:
- 37.5pg/mL
- Range:
- 62.5-4000pg/mL
- ELISA Type:
- Sandwich
- Reactivity:
- Human
- Sample Type:
- Serum, plasma and other biological fluids
- Research Area:
- Cell Biology
Description
Assay type: | Sandwich |
Format: | 96T |
Assay time: | 4.5h |
Reactivity: | Human |
Detection method: | Chemiluminescence |
Detection range: | 62.50-4000 pg/mL |
Sensitivity: | 37.50 pg/mL |
Sample volume: | 100µL |
Sample type: | Serum, plasma and other biological fluids |
Repeatability: | CV < 15% |
Specificity: | This kit recognizes Human CX40 in samples. No significant cross-reactivity or interference between Human CX40 and analogues was observed. |
This kit uses Sandwich-CLIA as the method. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human CX40. Standards or samples are added to the appropriate micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human CX40 and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well successively and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human CX40, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit (RLU) value is measured spectrophotometrically by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human CX40. The concentration of Human CX40 in the samples can be calculated by comparing the RLU of the samples to the standard curve.
UniProt Protein Function: | GJA5: One gap junction consists of a cluster of closely packed pairs of transmembrane channels, the connexons, through which materials of low MW diffuse from one cell to a neighboring cell. Defects in GJA5 are a cause of familial atrial standstill (FAS). Atrial standstill is an extremely rare arrhythmia, characterized by the absence of electrical and mechanical activity in the atria. Electrocardiographically, it is characterized by bradycardia, the absence of P waves, and a junctional narrow complex escape rhythm. Defects in GJA5 are the cause of familial atrial fibrillation type 11 (ATFB11). ATFB11 is a familial form of atrial fibrillation, a common sustained cardiac rhythm disturbance. Atrial fibrillation is characterized by disorganized atrial electrical activity and ineffective atrial contraction promoting blood stasis in the atria and reduces ventricular filling. It can result in palpitations, syncope, thromboembolic stroke, and congestive heart failure. Belongs to the connexin family. Alpha-type (group II) subfamily. |
UniProt Protein Details: | Protein type:Channel, misc. ; Motility/polarity/chemotaxis; Membrane protein, multi-pass; Membrane protein, integral Chromosomal Location of Human Ortholog: 1q21. 1 Cellular Component: connexon complex; cell projection; integral to plasma membrane; gap junction Molecular Function:gap junction hemi-channel activity Biological Process: gap junction assembly; negative regulation of glomerular filtration; positive regulation of vasodilation; protein oligomerization; positive regulation of vasoconstriction; artery morphogenesis; embryonic heart tube development; negative regulation of blood pressure; angiogenesis; skeletal development; transmembrane transport; potassium ion transport; embryonic limb morphogenesis Disease: Atrial Standstill 1; Atrial Fibrillation, Familial, 11 |
NCBI Summary: | This gene is a member of the connexin gene family. The encoded protein is a component of gap junctions, which are composed of arrays of intercellular channels that provide a route for the diffusion of low molecular weight materials from cell to cell. Mutations in this gene may be associated with atrial fibrillation. Alternatively spliced transcript variants encoding the same isoform have been described. [provided by RefSeq, Jul 2008] |
UniProt Code: | P36382 |
NCBI GenInfo Identifier: | 8928556 |
NCBI Gene ID: | 2702 |
NCBI Accession: | P36382. 3 |
UniProt Secondary Accession: | P36382,Q5T3B6, Q5U0N6, |
UniProt Related Accession: | P36382 |
Molecular Weight: | 40,380 Da |
NCBI Full Name: | Gap junction alpha-5 protein |
NCBI Synonym Full Names: | gap junction protein, alpha 5, 40kDa |
NCBI Official Symbol: | GJA5 |
NCBI Official Synonym Symbols: | CX40; ATFB11 |
NCBI Protein Information: | gap junction alpha-5 protein; connexin 40; gap junction protein alpha 5 40kDa |
UniProt Protein Name: | Gap junction alpha-5 protein |
UniProt Synonym Protein Names: | Connexin-40; Cx40 |
Protein Family: | Gap junction alpha-5 protein |
UniProt Gene Name: | GJA5 |
UniProt Entry Name: | CXA5_HUMAN |
As the RLU values of the standard curve may vary according to the conditions of the actual assay performance (e. g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.
Concentration (pg/mL) | RLU | Average | Corrected |
4000 | 57100 61062 | 59081 | 59046 |
2000 | 26472 29246 | 27859 | 27824 |
1000 | 14367 12601 | 13484 | 13449 |
500 | 6500 6710 | 6605 | 6570 |
250 | 3469 3017 | 3243 | 3208 |
125 | 1689 1473 | 1581 | 1546 |
62.50 | 739 771 | 755 | 720 |
0 | 34 36 | 35 | -- |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Human CX40 were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Human CX40 were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (pg/mL) | 216.55 | 500.70 | 1700.59 | 207.77 | 496.04 | 1629.53 |
Standard deviation | 23.69 | 53.12 | 143.19 | 24.60 | 38.39 | 106.25 |
C V (%) | 10.94 | 10.61 | 8.42 | 11.84 | 7.74 | 6.52 |
Recovery
The recovery of Human CX40 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
Serum (n=5) | 87-99 | 93 |
EDTA plasma (n=5) | 96-112 | 102 |
Cell culture media (n=5) | 92-106 | 100 |
Linearity
Samples were spiked with high concentrations of Human CX40 and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Serum (n=5) | EDTA plasma (n=5) | Cell culture media (n=5) | ||
1:2 | Range (%) | 85-100 | 92-107 | 95-111 |
Average (%) | 92 | 97 | 102 | |
1:4 | Range (%) | 100-113 | 92-104 | 102-113 |
Average (%) | 108 | 98 | 108 | |
1:8 | Range (%) | 102-120 | 97-110 | 93-106 |
Average (%) | 109 | 104 | 99 | |
1:16 | Range (%) | 98-111 | 88-102 | 91-105 |
Average (%) | 104 | 94 | 98 |
An unopened kit can be stored at 4°C for 1 month. If the kit is not used within 1 month, store the items separately according to the following conditions once the kit is received.
Item | Specifications | Storage |
Micro CLIA Plate(Dismountable) | 8 wells ×12 strips | -20°C, 6 months |
Reference Standard | 2 vials | |
Concentrated Biotinylated Detection Ab (100×) | 1 vial, 120 µL | |
Concentrated HRP Conjugate (100×) | 1 vial, 120 µL | -20°C(shading light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 4°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | |
HRP Conjugate Diluent | 1 vial, 14 mL | |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | |
Substrate Reagent A | 1 vial, 5 mL | 4°C (shading light) |
Substrate Reagent B | 1 vial, 5 mL | 4°C (shading light) |
Plate Sealer | 5 pieces | |
Product Description | 1 copy | |
Certificate of Analysis | 1 copy |
- Set standard, test sample and control (zero) wells on the pre-coated plate and record theirpositions. It is recommended to measure each standard and sample in duplicate. Note: addall solutions to the bottom of the plate wells while avoiding contact with the well walls. Ensuresolutions do not foam when adding to the wells.
- Aliquot 100 µL of standard solutions into the standard wells.
- Add 100 µL of Sample / Standard dilution buffer into the control (zero) well.
- Add 100 µL of properly diluted sample (serum, plasma, tissue homogenates and otherbiological fluids. ) into test sample wells.
- Cover the plate with the sealer provided in the kit and incubate for 90 min at 37 °C.
- Aspirate the liquid from each well, do not wash. Immediately add 100 µL of BiotinylatedDetection Ab working solution to each well. Cover the plate with a plate seal and gently mix. Incubate for 1 hour at 37 °C.
- Aspirate or decant the solution from the plate and add 350 µL of wash buffer to each welland incubate for 1-2 minutes at room temperature. Aspirate the solution from each well andclap the plate on absorbent filter paper to dry. Repeat this process 3 times. Note: a microplatewasher can be used in this step and other wash steps.
- Add 100 µL of HRP Conjugate working solution to each well. Cover with a plate seal andincubate for 30 min at 37 °C.
- Aspirate or decant the solution from each well. Repeat the wash process for five times asconducted in step 7.
- Add 100 µL of Substrate mixture solution to each well. Cover with a new plate seal andincubate for no more than 5 min at 37 °C. Protect the plate from light.
- Determine the RLU value of each well immediately.