Human Cell Biology ELISA Kits 3
Human AGR2 (Anterior Gradient Protein 2) CLIA Kit (HUES00218)
- SKU:
- HUES00218
- Product Type:
- ELISA Kit
- ELISA Type:
- CLIA Kit
- Size:
- 96 Assays
- Sensitivity:
- 18.75pg/mL
- Range:
- 31.25-2000pg/mL
- ELISA Type:
- Sandwich
- Synonyms:
- AG2, GOB-4, HAG-2, PDIA17, XAG-2
- Reactivity:
- Human
- Sample Type:
- Serum, plasma and other biological fluids
- Research Area:
- Cell Biology
Description
Assay type: | Sandwich |
Format: | 96T |
Assay time: | 4.5h |
Reactivity: | Human |
Detection method: | Chemiluminescence |
Detection range: | 31.25-2000 pg/mL |
Sensitivity: | 18.75 pg/mL |
Sample volume: | 100µL |
Sample type: | Serum, plasma and other biological fluids |
Repeatability: | CV < 15% |
Specificity: | This kit recognizes Human AGR2 in samples. No significant cross-reactivity or interference between Human AGR2 and analogues was observed. |
This kit uses Sandwich-CLIA as the method. The micro CLIA plate provided in this kit has been pre-coated with an antibody specific to Human AGR2. Standards or samples are added to the appropriate micro CLIA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for Human AGR2 and Avidin-Horseradish Peroxidase (HRP) conjugate are added to each micro plate well successively and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain Human AGR2, biotinylated detection antibody and Avidin-HRP conjugate will appear fluorescence. The Relative light unit (RLU) value is measured spectrophotometrically by the Chemiluminescence immunoassay analyzer. The RLU value is positively associated with the concentration of Human AGR2. The concentration of Human AGR2 in the samples can be calculated by comparing the RLU of the samples to the standard curve.
UniProt Protein Function: | AGR2: Required for MUC2 post-transcriptional synthesis and secretion. May play a role in the production of mucus by intestinal cells. Proto-oncogene that may play a role in cell migration, cell differentiation and cell growth. Interacts with LYPD3 and DAG1 (alphaDAG1). Interacts with MUC2; disulfide-linked. Expressed strongly in trachea, lung, stomach, colon, prostate and small intestine. Expressed weakly in pituitary gland, salivary gland, mammary gland, bladder, appendix, ovary, fetal lung, uterus, pancreas, kidney, fetal kidney, testis, placenta, thyroid gland and in estrogen receptor (ER)-positive breast cancer cell lines. Belongs to the AGR family. |
UniProt Protein Details: | Protein type:Secreted; Oncoprotein; Secreted, signal peptide Chromosomal Location of Human Ortholog: 7p21. 3 Cellular Component: endoplasmic reticulum; extracellular space Molecular Function:epidermal growth factor receptor binding; protein binding; protein homodimerization activity Biological Process: digestive tract morphogenesis; positive regulation of developmental growth; positive regulation of epidermal growth factor receptor signaling pathway |
UniProt Code: | O95994 |
NCBI GenInfo Identifier: | 67462105 |
NCBI Gene ID: | 10551 |
NCBI Accession: | O95994. 1 |
UniProt Related Accession: | O95994 |
Molecular Weight: | 19,979 Da |
NCBI Full Name: | Anterior gradient protein 2 homolog |
NCBI Synonym Full Names: | anterior gradient 2, protein disulphide isomerase family member |
NCBI Official Symbol: | AGR2 |
NCBI Official Synonym Symbols: | AG2; GOB-4; HAG-2; XAG-2; PDIA17; HEL-S-116 |
NCBI Protein Information: | anterior gradient protein 2 homolog |
UniProt Protein Name: | Anterior gradient protein 2 homolog |
UniProt Synonym Protein Names: | HPC8; Secreted cement gland protein XAG-2 homolog |
Protein Family: | Anterior gradient protein |
UniProt Gene Name: | AGR2 |
UniProt Entry Name: | AGR2_HUMAN |
As the RLU values of the standard curve may vary according to the conditions of the actual assay performance (e. g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.
Concentration (pg/mL) | RLU | Average | Corrected |
2000 | 50768 60674 | 55721 | 55693 |
1000 | 22327 25621 | 23974 | 23946 |
500 | 11189 10875 | 11032 | 11004 |
250 | 4927 5661 | 5294 | 5266 |
125 | 2733 2483 | 2608 | 2580 |
62.5 | 1411 1211 | 1311 | 1283 |
31.25 | 670 678 | 674 | 646 |
0 | 28 28 | 28 | -- |
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Human AGR2 were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Human AGR2 were tested on 3 different plates, 20 replicates in each plate.
Intra-assay Precision | Inter-assay Precision | |||||
Sample | 1 | 2 | 3 | 1 | 2 | 3 |
n | 20 | 20 | 20 | 20 | 20 | 20 |
Mean (pg/mL) | 110.65 | 170.57 | 861.73 | 114.70 | 186.33 | 864.08 |
Standard deviation | 9.96 | 19.31 | 63.34 | 12.15 | 19.88 | 57.55 |
C V (%) | 9.00 | 11.32 | 7.35 | 10.59 | 10.67 | 6.66 |
Recovery
The recovery of Human AGR2 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.
Sample Type | Range (%) | Average Recovery (%) |
Serum (n=5) | 89-101 | 94 |
EDTA plasma (n=5) | 84-98 | 91 |
Cell culture media (n=5) | 92-109 | 99 |
Linearity
Samples were spiked with high concentrations of Human AGR2 and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.
Serum (n=5) | EDTA plasma (n=5) | Cell culture media (n=5) | ||
1:2 | Range (%) | 100-116 | 100-114 | 86-101 |
Average (%) | 108 | 106 | 93 | |
1:4 | Range (%) | 95-109 | 87-103 | 89-102 |
Average (%) | 100 | 94 | 95 | |
1:8 | Range (%) | 102-115 | 99-114 | 88-103 |
Average (%) | 109 | 105 | 96 | |
1:16 | Range (%) | 87-97 | 99-114 | 85-99 |
Average (%) | 92 | 106 | 92 |
An unopened kit can be stored at 4°C for 1 month. If the kit is not used within 1 month, store the items separately according to the following conditions once the kit is received.
Item | Specifications | Storage |
Micro CLIA Plate(Dismountable) | 8 wells ×12 strips | -20°C, 6 months |
Reference Standard | 2 vials | |
Concentrated Biotinylated Detection Ab (100×) | 1 vial, 120 µL | |
Concentrated HRP Conjugate (100×) | 1 vial, 120 µL | -20°C(shading light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 4°C, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | |
HRP Conjugate Diluent | 1 vial, 14 mL | |
Concentrated Wash Buffer (25×) | 1 vial, 30 mL | |
Substrate Reagent A | 1 vial, 5 mL | 4°C (shading light) |
Substrate Reagent B | 1 vial, 5 mL | 4°C (shading light) |
Plate Sealer | 5 pieces | |
Product Description | 1 copy | |
Certificate of Analysis | 1 copy |
- Set standard, test sample and control (zero) wells on the pre-coated plate and record theirpositions. It is recommended to measure each standard and sample in duplicate. Note: addall solutions to the bottom of the plate wells while avoiding contact with the well walls. Ensuresolutions do not foam when adding to the wells.
- Aliquot 100µl of standard solutions into the standard wells.
- Add 100µl of Sample / Standard dilution buffer into the control (zero) well.
- Add 100µl of properly diluted sample (serum, plasma, tissue homogenates and otherbiological fluids. ) into test sample wells.
- Cover the plate with the sealer provided in the kit and incubate for 90 min at 37°C.
- Aspirate the liquid from each well, do not wash. Immediately add 100µL of BiotinylatedDetection Ab working solution to each well. Cover the plate with a plate seal and gently mix. Incubate for 1 hour at 37°C.
- Aspirate or decant the solution from the plate and add 350µL of wash buffer to each welland incubate for 1-2 minutes at room temperature. Aspirate the solution from each well andclap the plate on absorbent filter paper to dry. Repeat this process 3 times. Note: a microplatewasher can be used in this step and other wash steps.
- Add 100µL of HRP Conjugate working solution to each well. Cover with a plate seal andincubate for 30 min at 37°C.
- Aspirate or decant the solution from each well. Repeat the wash process for five times asconducted in step 7.
- Add 100µL of Substrate mixture solution to each well. Cover with a new plate seal andincubate for no more than 5 min at 37°C. Protect the plate from light.
- Determine the RLU value of each well immediately.