Hormone & Small Molecule ELISA Kits

Biotin ELISA Kit (UNFI0098)

(No reviews yet) Write a Review
SKU:
UNFI0098
Product Type:
ELISA Kit
Size:
96 Assays
Sensitivity:
10pg/ml
Range:
100-2000pg/ml
ELISA Type:
Competitive
Synonyms:
Biotin
Reactivity:
Universal

Description

Biotin ELISA Kit

system_update_alt Datasheet system_update_alt MSDS

Key Features

Save Time Pre-coated 96 well plate
Quick Start Kit includes all necessary reagents
Publication Ready Reproducible and reliable results

Overview

Product Name:

Biotin ELISA Kit

Product Code:

UNFI0098

Size:

96 Assays

Target:

Biotin

Detection Method:

Competitive ELISA, Coated with Antibody

Reactivity:

Universal

Sensitivity:

< 10pg/ml

Range:

100-2000pg/ml

Storage:

4°C for 6 months

Note:

For Research Use Only

Additional Information

Recovery:

Matrices listed below were spiked with certain level of Biotin and the recovery rates were calculated by comparing the measured value to the expected amount of Biotin in samples. Please contact us for more information.

Linearity:

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Biotin and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected. Please get in contact for more information.

Intra-Assay:

CV <8%

Inter-Assay:

CV <10%

Kit Components

Component Quantity Storage

ELISA Microplate (Dismountable)

8x12 strips

4°C for 6 months

Lyophilized Standard

2

4°C/ -20°C

Sample/Standard Dlution Buffer

20ml

4°C

Biotin-labeled Antibody (Concentrated)

120ul

4°C (Protection from light)

Antibody Dilution Buffer

10ml

4°C

HRP-Streptavidin Conjugate (SABC)

120ul

4°C (Protect from light)

SABC Dilution Buffer

10ml

4°C

TMB Substrate

10ml

4°C (Protection from light)

Stop Solution

10ml

4°C

Wash Buffer (25X)

30ml

4°C

Plate Sealer

5

-

Other materials required:

  • Microplate reader with 450 nm wavelength filter
  • Multichannel Pipette, Pipette, microcentrifuge tubes and disposable pipette tips
  • Incubator
  • Deionized or distilled water
  • Absorbent paper
  • Buffer resevoir

Protocol

*Note: Protocols are specific to each batch/lot. For the correct instructions please follow the protocol included in your kit.

Equilibrate the TMB substrate for at least 30 min at 37°C beforeuse. When diluting samples and reagents, they must be mixed completely andevenly. It is recommended to plot a standard curve for each test.

Step Procedure

1.

Set standard, test sample and control (zero) wells on the pre-coatedplate respectively, and then, record their positions. It isrecommended to measure each standard and sample in duplicate. Washplate 2 times before adding standard, sample and control (zero) wells!

2.

Add Sample and Biotin-detection antibody: Add 50µL of Standard, Blank or Sample per well. The blankwell is added with Sample Dilution Buffer. Immediately add 50 µL of biotin-labelled antibody workingsolution to each well. Cover with the plate sealer provided. Gently tap the plate to ensure thoroughmixing. Incubate for 45 minutes at 37°C. (Solutions are added to the bottom of micro-ELISA platewell, avoid touching plate walls and foaming).

3.

Wash: Aspirate each well and wash, repeating the process three timesWash by filling each well with Wash Buffer (approximately 350µL)using a squirt bottle, multi-channel pipette, manifold dispenser orautomated washer. Complete removal of liquid at each step is essentialto good performance. After the last wash, remove any remaining WashBuffer by aspirating or decanting. Invert the plate and pat it againstthick clean absorbent paper.

4.

HRP-Streptavidin Conjugate(SABC): Add 100µL of SABC workingsolution to each well. Cover with a new Plate sealer. Incubate for30minutes at 37°C.

5.

Wash: Repeat the aspiration/wash process for five times.

6.

TMB Substrate: Add 90µL of TMB Substrate to each well. Coverwith a new Plate sealer. Incubate for about 10-20 minutes at 37°C.Protect from light. The reaction time can be shortened or extendedaccording to the actual color change, but not more than 30minutes.When apparent gradient appeared in standard wells, you can terminatethe reaction.

0 Reviews

View AllClose